mirror of
https://github.com/skaringa/water-counter.git
synced 2025-07-04 20:37:56 +02:00
Ensure that trigger mode is set
This commit is contained in:
parent
964011e832
commit
21997a1d85
1 changed files with 3 additions and 0 deletions
3
wairc.py
3
wairc.py
|
@ -94,6 +94,9 @@ def main():
|
|||
if not ser.isOpen():
|
||||
print "Unable to open serial port %s" % port
|
||||
sys.exit(1)
|
||||
# set trigger mode
|
||||
ser.write(b'C\r\n')
|
||||
ser.write(b'T\r\n')
|
||||
|
||||
trigger_state = 0
|
||||
counter = last_rrd_count()
|
||||
|
|